Williams LH006W2B401L30
Williams LH006W2B401L30
Hover to zoom
1 Of 5

Williams 'H' Series Horizontal Fan Coil, Left Piping, 115V, 4 Coil Rows (CW or HW with Electric Heat) - 600 CFM, 67,090 BTU

Model:

LH006W2B401L30

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Continue Shopping With These Categories
Williams 'H' Series Horizontal Fan Coil, Left Piping, 115V, 4 Coil Rows (CW or HW with Electric Heat) - 600 CFM, 67,090 BTU
Williams 'H' Series Horizontal Fan Coil, Left Piping, 115V, 4 Coil Rows (CW or HW with Electric Heat) - 600 CFM, 67,090 BTU
Model: LH006W2B401L30
Product Discontinued
Accessories
Features
Specifications
Reviews
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    Engineered for concealed or exposed ceiling applications, these top quality units come with multiple options and can be ordered with or without return-air plenums. The low profile and flexible design of the Horizontal Basic (LH-B) fan coil is ideal for multiple applications. The slim, compact design is well suited for drop-ceiling, closet, hallway and other concealed applications. The LH-B comes with a powder-coated epoxy drain pan and a wide range of coil, motor and controls options. These models have no exterior cabinet.
  • Williams H062401L30 Features
  • Heavy-gauge, galvanized steel construction.
  • Two-pipe or Four-pipe hydronic heating and/or cooling. Four-pipe system may be converted to a two-pipe system by capping off one set of pipes. Manual are-vents on water coils.
  • Coils are 1/2" OD copper tubes with aluminum fins (12 FPI) and tested underwater at 350 PSI with a 300 PSI working pressure.
  • Drain pan is black epoxy, powder-coat finish, insulated with 1/4" elastomeric insulation, and has both primary and secondary drain connections.
  • Three-speed, 115V or 208V/1/60Hz PSC motor with quick-connect plug wired to a junction box.
  • Motors are factory-wired and terminated in a junction box for single-point power supply.
  • One-inch duct collar on return-air and supply-air openings.
  • Optional return-air plenum has an easily accessible, 1" fiberglass, throwaway filter.
  • Rear and bottom return-air plenums are insulated with neoprene-coated, over three pound density, 1/2" fiberglass insulation.
  • 100% factory leak and performance tested.
California residents see
Warning: This product can expose you to chemicals including Epichlorohydrin which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

LH006W2B401L30
specs product image PID-43934
General Information
Product Line
H
Blower Motor Type
Multi-Speed
Coil Type
Hydronic
Motor Type
PSC
Configuration Learn More
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Horizontal
Electric Heat
Included
Additional Model Numbers

H062401L30, LH006W2B401L30

Performance
Heating BTU
67090
Electric Heat Capacity
3 kW
Nominal Maximum Cooling Capacity
17700 BTU
Maximum Air Flow
600 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Cold Water Inlet
1/2 Inch
Hot Water Outlet
1/2 Inch
Hot Water Inlet
1/2 Inch
Cold Water Outlet
1/2 Inch
Product Height
9 1/2 Inches
Product Width
40 1/2 Inches
Product Depth
21 3/4 Inches
Product Weight
117 Pounds
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year

Reviews

Williams LH006W2B401L30 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
Replacing HVAC equipment after a flood
Replacing HVAC equipment after a flood
"Water got into my furnace!" It's a complaint I hear all too often when people ...
How to Pick the Perfect Hot Water Towel Warmer
How to Pick the Perfect Hot Water Towel Warmer
Hydronic towel warmers are a great way to take advantage of your existing hot w...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Williams 'H' Series Horizontal Fan Coil, Left Piping, 115V, 4 Coil Rows (CW or HW with Electric Heat) - 600 CFM, 67,090 BTU
Williams LH006W2B401L30
Customer Review Images